Left Lamp in an Alarm State

 

We recently replaced the left and right UV curing lamps, we followed all of the steps for replacing the lamps as is listed in the maintainance guide.

We pulled both housings out and replaced the lamps, put everything back together as before and installed the lamp housings back onto the carriage and connected all of the wiring and air supply

Turned the main power switch back to the on position and started the press, The press follows its usual start up procedure and ignites both lamps and continues to warm them. The right lamp usually heats up first and begins the high power mode on the Fan to cool it, right before the left lamp gets to ready mode the press shuts everything down and comes up with these Error messages in this order.

Left Lamp is in an Alarm State

Waste can is full

Door is open

Left Lamp communication has failed

Right Lamp communication has failed

Carriage lift drive communcation has failed

 

I would like to note that if I press the Green start button on the press and select Restart, the press will start up fine and both lamps will ignite and fully warm and will allow me to print without any further issue.

But if the press cools down and typically if I switch off the main power, the error will appear again.

 

We have done the following to try and diagnose the issue:

Removed both housings and switched the left and right lamp, Error still appears "Left Lamp is in an Alarm State" when started up

Removed the Fan controller board from both Housings and switched, Same error appears

Checked and Checked connections to the Left housing.

Both housing fans are functioning normally,

Both Shutters are operating normally,

 

We did put some High Temp shutter grease on the left housing because the shutters were making noise, Noise has stopped and I also went back and wiped excess grease to see if it wasnt allowing the shutters to move as freely.

Also tighted a few screws holding the shutters themselves aswell as the air piston for the shutters.

 

On the PC I opened up the Sensors window, under Hardware sensors it is as follows

Door: Illumated   (Checked All doors)

EStop: Not Illuminated

EStop Latch: Not Illuminated

Waste Can Full: Illuminated  (Waste can is not full)

Maintainance Fluid Can Empty: Illuminated  (Full of Fluid)

 

Main Air: Illumated



__________________
Newbie
Status: Offline
Posts: 3
Date:
sorry me
but i have same problem.
How did you solved?